Timber Design for RSTAB 9
by Dlubal, Structural analysis
Strength, stability, serviceability and fire checks of timber members in RSTAB 9
RSTAB 9 and its add-ons
RSTAB 9 is the main program for beams, frames and trusses; the add-ons are bought separately, whenever you need them. Click an add-on to see what it does and its price.
Main programs 1
-
RSTAB 9
Structural analysis of frames and trusses for civil engineers
from 2.345 € per year
- Structures: bars, frames, trusses
- Analysis: linear and non-linear
- Design: with add-ons
Design 6
-
Steel Design
Strength, stability and serviceability checks of steel members in RSTAB 9
from 2.065 € per year
- Limit states: ultimate and serviceability
- Standards: Eurocode 3 and other international standards, e.g. AISC 360
- Sections: rolled, hollow, parametric, built-up, from RSECTION
-
Stress-Strain Analysis
Stress analysis of RSTAB 9 members against limit stresses
from 945 € per year
- Objects: members and member sets
- Stresses: normal, shear, equivalent
- Limit stress: from the material or user-defined, also by sign
-
Concrete Design
Reinforced concrete in RSTAB 9: beams, columns and member sets
from 2.065 € per year
- Elements: members and member sets: beams and columns
- Limit states: ultimate and serviceability, with detailing rules
- Reinforcement: longitudinal, transverse and torsional per member
-
Concrete Foundations
Geotechnical checks and design of concrete foundations inside RSTAB 9
from 875 € per year
- Foundation types: reinforced and unreinforced plates, bucket, block, stepped
- Bucket sides: smooth or rough
- Geotechnical checks: bearing capacity, sliding, uplift, overturning
-
Aluminum Design
Strength, stability and serviceability checks of aluminium members in RSTAB 9
from 1.365 € per year
- Limit states: ultimate and serviceability
- Standards: various, including ADM
- Sections: rolled, hollow, parametric, built-up, RSECTION
-
Timber Design
Strength, stability, serviceability and fire checks of timber members in RSTAB 9
from 1.505 € per year
- Limit states: ultimate, serviceability and fire
- Standards: EN 1995, AS 1720, GB 50005 and others
- Sections: rectangular, circular, T, built-up, parametric
Dynamic analysis 4
-
Modal Analysis
Natural frequencies, periods and mode shapes of frame structures in RSTAB 9
from 945 € per year
- Program: RSTAB 9 (add-on)
- Solvers: Subspace Iteration, shifted inverse power method
- Eigenvalues: up to 9,999
-
Response Spectrum Analysis
Seismic analysis with response spectra and equivalent static loads in RSTAB 9
from 1.085 € per year
- Program: RSTAB 9 (add-on)
- Method: multi-modal response spectrum analysis
- Codes: EN 1998-1 (25+ National Annexes, incl. ELOT), ASCE 7, NBC, SIA 261 and others
-
Time History Analysis
Dynamic analysis in the time domain for time diagrams and earthquakes in RSTAB 9
from 1.015 € per year
- Program: RSTAB 9 (add-on)
- Excitation: force-time diagrams, support accelerograms
- Linear solvers: linear modal, linear implicit Newmark
-
Pushover Analysis
Pushover analysis in RSTAB 9: capacity curve and target displacement to EC 8
from 1.015 € per year
- Program: RSTAB 9 (add-on)
- Plastic hinges: steel to FEMA 356 and EN 1998-3
- Nonlinear material: masonry, bilinear steel, your own diagrams
Additional analyses 2
-
Structure Stability
Critical load factors and buckling modes of member structures in RSTAB 9
from 1.015 € per year
- Methods: eigenvalue and incremental (nonlinear)
- Eigenvalue solvers: Subspace Iteration, Shifted Inverse Iteration
- Activation: in a load case or combination, and via combination wizards
-
Torsional Warping (7 DOF)
Cross-section warping as a 7th degree of freedom in RSTAB 9 member analysis
from 1.225 € per year
- Degrees of freedom: 7 (ux, uy, uz, φx, φy, φz, ω)
- Internal forces: 8, including Mt,pri, Mt,sec and bimoment Mω
- Analyses: linear static, second-order, large deformation
Special solutions 1
-
Optimization & Costs / CO2
Optimisation of parametric member models in RSTAB 9 with particle swarm (AI)
from 1.155 € per year
- Program: RSTAB 9 (add-on)
- Methods: particle swarm optimization (PSO), batch processing
- Criteria: minimum weight or minimum deformation
First-licence prices for Greece and Cyprus, excluding VAT. The add-ons work inside RSTAB 9.
Timber members checked inside RSTAB 9
Choose a topic and see what Timber Design checks, from simple beams to towers and domes.
From roof trusses to free forms
Common and parametric timber sections are checked, as well as members with tapered or curved geometry.
- Rectangular, square, T, circular, built-up and parametric sections
- Tapered, curved and arched members, including their stability
- Timber materials and LVL to EC 5
- Eurocode 5 and other international standards
Compression perpendicular to the grain, at supports and nodes
The special checks of timber follow the standard, with no hand calculations.
- Compression perpendicular to the grain at end and intermediate supports
- Reinforcement with fully threaded screws to EC 5
- At nodes with several members, using the internal forces of the connected members
- Notches and the system strength factor ksys to EN 1995-1-1
Lateral-torsional buckling with an eigenvalue analysis
Mcr is calculated with an optional eigenvalue analysis inside the checks, and the mode shape is shown graphically.
- Eigenvalue analysis for Mcr, integrated into the checks
- Lateral restraints set separately for fire or for wind suction
- Alternatively, second-order analysis, imperfections and stiffness reduction in the internal forces
- Optionally together with the Torsional Warping (7 DOF) add-on
Deflections with relative and absolute limits
In the serviceability limit state you decide how deflection limits combine, and sections can be optimised.
- Relative and absolute limit, with their sum, the smaller or the larger governing
- Section optimisation in the serviceability limit state too
- Design supports that split the member into segments for the deflection check
Clear formulas, no black box
Checks appear in tables with every detail and graphically on the model.
- Tables of checks with all result details
- Graphical display of the results on the model
- Full transfer to the RSTAB printout report
- Results are kept when settings change, and only invalid ones are recalculated
Towers, bridges and halls with RSTAB
Dlubal provides ready models for RSTAB and presents real projects designed with it.
- Models to download: round timber hall, carport, timber roof, salt storage hall
- Timber lookout towers in Frankfurt and in Ireland
- An 1852 Howe truss bridge in Kempten, with Timber Design and Steel Design
- Airship hangar with glulam arches spanning 42 m
Timber structures in RFEM 6 and RSTAB 9
Official Dlubal video on the analysis and design of timber structures.
See it in action
The video or demo loads only when you press play.
What it does, stage by stage
The Timber Design add-on designs timber members inside RSTAB 9 and checks them in the ultimate limit state (cross-section resistance and stability), in the serviceability limit state and for fire, to Eurocode 5 and other international standards. Input and result evaluation take place inside the RSTAB interface.
It accepts rectangular, square, T and circular sections, built-up and irregular parametric sections, as well as tapered and curved or arched members. For resistance it checks tension, compression, bending, shear, torsion and their combinations, compression perpendicular to the grain at end and intermediate supports (without reinforcement or, to EC 5, with fully threaded screws) and notches. The system strength factor ksys for similar components close together is applied to EN 1995-1-1.
For stability there is an optional eigenvalue analysis for Mcr, integrated into the design checks. Lateral restraints and lateral-torsional bracing can be defined separately for the fire design or for a reversed moment distribution, e.g. from wind suction. Alternatively, all stability effects are included in the RSTAB internal forces (second-order analysis, imperfections, stiffness reduction), also with the Torsional Warping add-on.
Results are shown in tables and graphically on the model, and every check shows its formulas, with no black box. Everything goes into the RSTAB printout report. Dlubal presents timber lookout towers, truss bridges and glulam arch halls designed with it.
Features
Features
- Limit states
- ultimate, serviceability and fire
- Standards
- EN 1995, AS 1720, GB 50005 and others
- Sections
- rectangular, circular, T, built-up, parametric
- Members
- tapered, curved and arched
- Section resistance
- tension, compression, bending, shear, torsion, combinations
- Supports
- compression perpendicular to grain, also with fully threaded screws
- Special checks
- notches, system strength factor ksys
- Stability
- eigenvalue analysis for Mcr, separate restraints for fire
- Results
- tables, graphics, formulas, RSTAB report
All features
- Wide range of sections: rectangular, square, T, circular, built-up, irregular parametric and others (depending on the standard)
- Design of timber materials and laminated veneer lumber (LVL) to EC 5
- Design of tapered and curved members (method depending on the standard)
- Adjustment of the essential design factors and standard parameters
- Flexibility through detailed settings for the basis and extent of the calculations
- Fast, clear overview of the result distribution right after the design
- Detailed output of the results with the essential formulas, so the result path can be followed
- Numerical results in windows and graphical display on the model
- Results integrated into the RSTAB printout report
- Design for tension, compression, bending, shear, torsion and combined internal forces
- Compression perpendicular to the grain at end and intermediate supports, without reinforcement or, to EC 5, with fully threaded screws
- Compression perpendicular to the grain at nodes with several members, using the internal forces of the connected members
- Design of special shapes such as curved and arched members, including their stability
- Lateral restraints and lateral-torsional bracing defined separately for the fire design and for a reversed moment distribution (e.g. wind suction)
- Consideration of notches
- System strength via the factor ksys to EN 1995-1-1, 6.6(1)-(3)
- Traceability of all design checks with clear formulas
- Optional stability design with an eigenvalue analysis (Mcr calculation) integrated into the design checks
- Optional combination with the Torsional Warping (7 DOF) add-on
- Alternatively, all stability effects in the RSTAB internal forces (second-order analysis, imperfections, stiffness reduction)
System requirements
Operating system Windows
- Requires an RSTAB 9 licence
- For stability with warping (7 degrees of freedom): Torsional Warping add-on, optional
Works well with, and alternatives
Works well with
Alternatives

from Was 1.950 € 1.365 € per year, excl. VAT

from Was 1.650 € 1.155 € per year, excl. VAT

from Was 1.550 € 1.085 € per year, excl. VAT
Timber Design for RSTAB 9 next to alternatives
Open the full comparisonQuestions, licence and delivery
What do I need to run it?
An RSTAB 9 licence. Timber Design is an add-on for RSTAB 9 and uses the structure and internal forces of the same model.
Which standards does it support?
Eurocode 5 and other international standards, including the Australian AS 1720 and the Chinese GB 50005.
Does it check compression perpendicular to the grain?
Yes, at end and intermediate supports, without reinforcement or, to EC 5, with fully threaded screws. At nodes with several members it can also consider the internal forces of the connected members.
How is stability checked?
With an optional eigenvalue analysis for Mcr inside the design checks, or with all effects in the RSTAB internal forces (second-order analysis, imperfections, stiffness reduction), also with the Torsional Warping add-on.
Does it do a fire resistance design?
Yes. The fire design is included, and the lateral restraints for buckling can be defined separately for the fire situation.
Can I buy or rent it?
Both: it is available as a perpetual licence or rented for 1, 3, 6 or 12 months.
How do I receive the licence?
After payment we order the licence from the manufacturer and email you its details.
Do the prices include VAT?
Prices exclude VAT. With a valid VAT number from another EU country, VAT is not charged; in Belgium it is charged at 21%. For private customers, VAT is calculated at checkout.






