Fenix Plus 3
by MST Software, Safety & simulation
Fire (FDS) and evacuation simulation in one program, with ASET/RSET analysis (price on request)
Fenix Plus 3 from model to conclusion
Choose a topic to see how the program builds the building, moves the crowd, burns and compares the times.
One 3D model for every simulation
You build the building once and use it for both evacuation and fire. The editor handles complex shapes, several levels and atriums.
- Walls, doors, windows and other objects, with precise drawing tools
- Floor plans as images (JPG, PNG, BMP), with scaling, rotation, distortion correction and transparency per level
- Topology imported from DWG/DXF, so you do not redraw from scratch
- Direct IFC import from BIM models
- Scenarios that combine geometry, evacuation and fire, and adapt without a new model
Works with: JPG PNG BMP DWG DXF IFC
Every person moves independently, with no artificial zones
You do not divide the building into zones: you define the obstacles and people move freely in every direction.
- Search for the shortest route to an exit, avoiding obstacles and collisions
- Preference for less crowded exits, or specific exits for specific groups
- Profile editor: height, projected area, colour and the relation between speed and flow density
- Separate speeds per group on ramps, stairs and spiral stairs
- Flow density maps that show where bottlenecks form
Fire is calculated with NIST’s FDS
Fenix Plus 3 creates the input file FDS needs from your model, so you do not write parameters by hand.
- Three-dimensional fire development, with smoke, heat, toxic gases and reduced visibility
- Automatic conversion of scene objects into the FDS format (.fds file)
- Calculation areas with different cell sizes where more accuracy is needed
- Air leakage through closed openings too, which affects how the fire spreads
- Work with real objects (walls, doors, windows) before the scene goes to FDS
Works with: FDS
Available time against required time
Fire and evacuation results are compared inside the same program, at every registering point.
- Evacuation time compared with blocking time at each registering point
- Distributions of the dangerous fire factors and evacuation flow maps
- Numerical values and images for checking the results
- Results are updated continuously, so you always see the latest data
- Reporting module to document the study
What it does, stage by stage
Fenix Plus 3 from MST Software is a single program for performance-based fire safety studies: you build the 3D model of the building, run fire and evacuation simulations and compare the available with the required safe egress time (ASET/RSET).
The fire is calculated with FDS (Fire Dynamics Simulator by NIST): fire growth, smoke, heat, toxic gases and visibility. The evacuation simulates each person individually: they follow the shortest route, avoid obstacles and other people, and change exit when an exit becomes crowded. Speeds on ramps and stairs are set separately.
Floor plans are imported as images or DWG/DXF, BIM models as IFC and point clouds as PTX. Results are shown in 3D or in VR glasses and are turned into a report. It runs on 64-bit Windows only. The licence is time-limited (3, 6 or 12 months) for one computer, with support and updates for as long as it is valid.
Features and files
Features
- Fire
- FDS 6.9.1 and Smokeview included in the installation package
- Evacuation
- each person individually, routes and exits per group
- Analysis
- ASET/RSET at recording points
- Import
- images, DWG/DXF (up to AutoCAD 2010), IFC 2x3/IFC4, PTX, FDS
- Export
- FDS input files, reports
- Display
- 3D and VR glasses, video recording
- Licence
- 3, 6 or 12 months, one computer
- Trial
- free Demo with limits, no expiry
Opens and saves
- .dwg
- .dxf
- .ifc
System requirements
Operating system Windows
- Windows 10 64-bit (recommended); 64-bit only
- Recommended: six-core Intel Core i7 or equivalent, 16 GB RAM or more, 1920×1080 display, NVIDIA or AMD graphics card
- Minimum: dual-core Intel Core i3, 2 GB RAM, 1024×768 display
- MS Word 2010 or later to view the reports
- The manufacturer notes that the requirements grow with the size of the project
Works well with, and alternatives
Works well with
Fenix Plus 3 next to alternatives
Open the full comparisonQuestions, licence and delivery
What licences are there?
Time-limited licences of 3, 6 or 12 months for one computer (node-locked). The manufacturer does not mention a perpetual or floating licence. The licence is transferred to another computer on request to support.
Is there a trial version?
Yes, the free Fenix Plus 3 Demo, with no expiry. It does not produce reports and has size limits, e.g. up to 2 floors, 80 people and 200 seconds of fire simulation. It runs the calculations on the manufacturer's server, so an internet connection is required.
What does the licence include?
The whole program (fire, evacuation, ASET/RSET), with support and updates for as long as the licence is valid.
Does it open Revit or ArchiCAD models?
Through IFC (2x3 or IFC4): doors, slabs, stairs and openings are recognised, and the other elements become obstacles. Floor plans can also be imported as DWG/DXF.
How do I receive the licence?
After payment we order the licence from the manufacturer and email you its details.
Do the prices include VAT?
Prices exclude VAT. With a valid VAT number from another EU country, VAT is not charged; in Belgium it is charged at 21%. For private customers, VAT is calculated at checkout.